Automatic Rockwell and Superficial Rockwell Hardness Tester, engineered to meet the rigorous standards set forth by ASTM E18, ISO 6508, and ISO 2039-2. This advanced testing instrument employs a high precision load cell and Closed-Loop electronic control with a 1 KHz sampling rate, ensuring optimal accuracy and reliability.
To begin testing, users simply rotate the handwheel, raising the screw until the standard block makes contact with the indenter, confir- med by the system’s buzzer and “OK” status on the display. At this point, the initial test force is applied, and the motor automatically initiates the application of the main test force. Once the dwelling time reaches zero, the system automatically releases the main test force, retaining the initial force for final measurement.
Software
The advanced hardness testing system features a comprehensive and intuitive interface divided into five sections: Setting, Testing, Display, Diagram, and Programming. It supports various international standards (ASTM E140, DIN18625, GB/T) and hardness scales (HRA, HRB, HRC, etc.), allowing users to customize their testing needs.
To ensure accuracy, the system allows for the adjustment of dwelling time from 0 to 60 seconds and can test curved surfaces, correcting results based on the curvature radius. Users can set standard values and deviation limits to facilitate quick assessment of product pass/fail status. The testing process is automated: simply rotate the handwheel to initiate the test, with visual and audible confirmations. Once the dwelling time is reached, the main force is automatically released, allowing for accurate final measurement.TECHNICAL FEATURE
MODELATI RS
Compliance standardsASTM E18, ISO 6508 and ISO 2039-2
Hardness scales
HRA, HRD, HRC, HRF, HRB, HRG, HRH, HRE, HRK, HRL, HRM, HRP, HRR, HRS, HRV, HRN, HRT, HRX, HRS, ISO 2039-2
Conversion scales
HV, HK, HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HS, HBWInitial test force
3 Kg (29.42 N), 10 Kg (98.07 N)Total test force
15 Kg (147.1 N), 30 Kg (294.2 N), 45 Kg (441.3 N), 60 Kg (588.4 N), 100 Kg (980.7 N), 150 Kg (1471 N)
Brinell test force62.5 Kg (613N), 125 Kg (1226.2 N), 187.5 Kg (1839.4 N) (at request) Dwell time
Adjustable from 2 to 60 secondsMax height of test piece
230 mm (300mm at request)
Depth capacity of throat170 mm
Power supply220V / 110V , 50 Hz / 60 Hz
Total dimensions475 x 200 x 700 mm - Reviews
-