GIANT FORCE LED Tester Series Programmable Light Bar Life Tester (Light Bar LED)

GIANT FORCE LED Tester Series Programmable Light Bar Life Tester (Light Bar LED)

฿0.00

Tj less than 85°C when ambient temperature is 25°C.
Tj less than 125°C when ambient temperature is 85°C.
Suitable for 5W below, Star, Square, Dip packaged.
Max 200 pieces/5W (High Power), CC mode, jump-free output.
Color touch screen, programmable.
Jigs and aluminum base included.
Optional: base temperature, voltage and current scanning and recording system.

Brand GIANT FORCE
OR
Description

Details

Programmable Light Bar Life Tester (Light Bar LED)

Tj less than 85°C when ambient temperature is 25°C.
Tj less than 125°C when ambient temperature is 85°C.
Suitable for 5W below, Star, Square, Dip packaged.
Max 200 pieces/5W (High Power), CC mode, jump-free output.
Color touch screen, programmable.
Jigs and aluminum base included.
Optional: base temperature, voltage and current scanning and recording system.

 

Specification:

Model

(PLBL- 40- V/I -CP - SD)

Exterior dimension

480 * 510 * 560 cm (W*H*D) (including projected parts)

Standard Channel

5 channel/module/87.5w (max 40channel/set)

Maximum control Module

8 module/700w

Method of Test setting

Set module (start/stop) ; each module single control ,can set different current & data 

Output voltage/current range

0~35V/ 0~500mA(0.1V/1mA/Step)/channel 

Operation mode

CC/CV Switch

Sample rate & com interface

200ms (Sample to Controller) , 5sec (Sample to PC) & RS485

Continuous Mode
ON-OFF Mode

PULSE Mode

Continuous output capable
Selectable ON-OFF pulse wave settings (0~999.9sec), cycle setting (5 digits)
Pulse modes selectable; peak pulse current; 1/10 duty pulse width (1ms)

Current Set/Max test time

Test current & volt –10CH(setting of bias positive current & volt --test positive current & volt setting) / 9999.9Hr

Data reading & link number 
of machines

read / record value of the voltage & current & temp. of channel and T/H values of each Chamber /max 32 Set

Output & indicator

1% ± 2mA & 0.1V/1mA

Voltage / Current values Conversion curve

Record the voltage and current values of each Channel can convert the Curve

Voltage /Current/Temp. Analysis

Recording of the start /sample / end time of voltage/ current/ temp.

Excel report conversion

Set condition data, measurement data and voltage shortage datd converted as Excel file

Power Source

AC110V/10A & 220V/5A , 50/60Hz

Reviews
5 star
0
4 star
0
3 star
0
2 star
0
1 star
0

Image