  Programmable Multi-channel DC Power Supply
PMCD-18W-200-CP-SD
PMCD-18W-40-CP-SD
PMCD-1W-400-CP-SD

  Specification:
Model PMCD-18W-200-CP-SD
Exterior dimension 480 * 600 * 600 mm (W*H*D)(including projected parts)
Standard Channel A/B Port each 10 channel/module/360w (max 200 channel/set)
Maximum control Module 10 module/3.6 KW
Method of Test setting Set module (start/stop) ; each module A/B single control ,can set different current & data
Output voltage/current range 0~12V/ 0~1500mA(1mA/Step)/channel
Operation mode CC
sample rate & com interface 1Sec~59:59mm:ss (Sample to Controller) , 5 sec (Sample to PC) & RS485 or RS232
Continuous Mode
ON-OFF Mode

PULSE Mode
Select Continuous Mode 
Allow Switch ON-OFF Pulse Set(0~59,59mm:ss), cycle set function
(decimal)
Allow Switch pulse model;peak pulse current ;1/10 duty pulse width (1mS)
Current Set/Max test time Bias & Test current –10CH(setting of bias positive current /test positive current setting) / 9999.9Hr
Data reading & link number of machines read /record value of the voltage & current & temp. of channel and T/H values of each Chamber /max 32 Set
Output & indicator 1%±2mA & 0.1V/1mA
Voltage / Current values Conversion curve record the voltage and current values of each Channel can convert the Curve
Voltage /Current/Temp. Analysis Recording of the start /sample/ end time of voltage/ current/ temp.
Excel report conversion Set condition data, measurement data and voltage shortage data converted as Excel file
Power Source AC 220V/25A , 50/60Hz

Model PMCD-18W-40-CP-SD
Exterior dimension 480 * 400 * 510 mm (W*H*D)(including projected parts)
Standard Channel 5 channel/module/87.5w (max 40channel/set)
Maximum control Module 8 module/700W
Method of Test setting Set module (start/stop) ; each module single control ,can set different current &data
Output voltage/current range 0~35V/ 0~500mA(0.1V/1mA/Step)/channel
Operation mode CC/CV Switch
sample rate & com interface 1Sec~59:59mm:ss (Sample to Controller) , 5 sec (Sample to PC) & RS485 or RS232
Continuous Mode
ON-OFF Mode

PULSE Mode
Select Continuous Mode 
Allow Switch ON-OFF Pulse Set(0~59,59mm:ss), cycle set function
(decimal)
Allow Switch pulse model;peak pulse current ;1/10 duty pulse width (1mS)
Current Set/Max test time Test current & volt –10CH(setting of bias positive current & volt --test positive current & volt setting) / 9999.9Hr
Data reading & link number of machines read /record value of the voltage & current & temp. of channel and T/H values of each Chamber /max 32 Set
Output & indicator 1%±2mA & 0.1V/1mA
Voltage / Current values Conversion curve record the voltage and current values of each Channel can convert the Curve
Voltage /Current/Temp. Analysis Recording of the start /sample/ end time of voltage/ current/ temp.
Excel report conversion Set condition data, measurement data and voltage shortage data converted as Excel file
Power Source AC 220V / 7A , 50/60Hz

Model PMCD-1W-400-CP-SD
Exterior dimension 480 * 400 * 510 mm (W*H*D)(including projected parts)
Standard Channel A/B Port each 10 channel/module/40w (max 400channel/set)
Maximum control Module 10 module/400W
Method of Test setting Set module (start/stop) ; each module A/B single control ,can set different current & data
Output voltage/current range 0~5V/ 0~200mA(1mA/Step)/channel
Operation mode CC
sample rate & com interface 1Sec~59:59mm:ss (Sample to Controller) , 5sec (Sample to PC) & RS485 or RS232
Continuous Mode
ON-OFF Mode

PULSE Mode
Select Continuous Mode 
Allow Switch ON-OFF Pulse Set(0~59,59mm:ss), cycle set function
(decimal)
Allow Switch pulse model;peak pulse current ;1/10 duty pulse width (1mS)
Current Set/Max test time Bias & Test current –10CH(setting of bias positive current /test positive current setting) / 9999.9Hr
Data reading & link number of machines read /record value of the voltage & current & temp. of channel and T/H values of each Chamber /max 32 Set
Output & indicator 1%±2mA & 0.1V/1mA
Voltage / Current values Conversion curve record the voltage and current values of each Channel can convert the Curve
Voltage /Current/Temp. Analysis Recording of the start /sample/ end time of voltage/ current/ temp.
Excel report conversion Set condition data, measurement data and voltage shortage data converted as Excel file
Power Source AC 220V/ 4A , 50/60Hz